LostSouls.world

Crown Landmark / Exterior candidate C02

The exterior.
Closer to the artwork.

A second isolated candidate beside the preserved C01 baseline, addressing the R06 differences: flared ribs, curved podium cantilevers and an upper taper. Visual match, room fit and engine acceptance remain pending.

C02 exterior candidate, elevated view of the actual editable mesh
PI-BLD-0001-V01 · SHELL C02 · concept candidate
Actual model render · not an approved design match

2026-10-16 · isolated review asset · C01 baseline preserved · original artwork and INT R02 layouts unchanged

Download website package, GLB excluded / ZIPEditable model / OBJRead-first guideFit coverage / ZIP
Geometry exists240 m above ground

162 named parts, six saved views. The R06 foot and tip centres are retained exactly.

Measured fit75 / 81 fit

All 81 unchanged INT R02 rooms measured. 1.2 m allowance is a proposal.

Still openVisual · fit · engine

The silhouette is still more columnar than the artwork; see why below. No Blender or Unreal run is claimed.

Creator decision / still open

Choose the silhouette before revising the rooms.

These are the existing C02 candidate and C02T study, compared using the same unchanged INT R02 room rectangles. The renders show shape; the plans and table show the measured room conflict. Perspective images are qualitative comparisons, not calibrated overlays.

Open controlling R06 front reference Compare original front and rear

Upper rooms outside the earlier-taper study skin / measured margins before the proposed 1.2 m allowance
Level / roomProgramC02 marginC02T margin
L25-RM083Cross corridor / view end2.1 m-2.05 m / outside
L26-RM083Cross corridor / view end1.94 m-2.42 m / outside
L25-RM001Founders council2.67 m-1.69 m / outside
L25-RM002Council waiting2.01 m-3.9 m / outside
L25-RM003Celebration room2.01 m-3.9 m / outside
L25-RM004Council anteroom2.67 m-1.69 m / outside
L25-RM005Council service access2.67 m-1.69 m / outside
L25-RM006Upper pantry2.1 m-2.05 m / outside
L26-RM001Diplomacy lounge1.84 m-4.35 m / outside
L26-RM002Breakfast negotiation1.84 m-4.35 m / outside
L26-RM003Private office1.66 m-4.35 m / outside
L26-RM004Secured records1.41 m-3.15 m / outside
L26-RM005Private vestibule1.41 m-3.15 m / outside
L26-RM006Diplomacy support1.84 m-4.35 m / outside
L26-RM007Interconnecting vestibule2.61 m-1.95 m / outside
L26-RM008East staff link1.94 m-2.42 m / outside

Codex recommendation / proposal

Explore the reference-style silhouette first, then resize or relocate only the affected upper rooms around their story and gameplay roles. A room-fit pass alone cannot choose the building's visual identity. This recommendation selects neither option and approves no room changes.

Decision to record: retain the upper room blocks and the later taper, or authorize an isolated earlier-taper and upper-room revision study. Exact replacement dimensions, circulation and playable routes would still need design and validation. The podium, suite, enclosure and wall-assembly decisions remain open in either option.

All 81 rooms measured

75 fit. 6 need a decision.

Every unchanged room rectangle was tested at its floor and clear-height top against the enclosure that governs its level, read from the actual C02 mesh. Which enclosure governs a level is interpreted (L00–L02 → tier-1 wall and Deck 1; L03 → tier-2 wall and Deck 2; L25/L26 → tower skin) and needs a recorded decision.

RoomStatusWall marginNote
Arrival atrium
L00-RM001
inside below allowance0.4 mBelow the proposed 1.2 m allowance
West atrium gallery
L01-RM001
inside below allowance0.4 mBelow the proposed 1.2 m allowance
East atrium gallery
L01-RM002
inside below allowance0.4 mBelow the proposed 1.2 m allowance
West atrium gallery
L02-RM001
inside below allowance0.4 mBelow the proposed 1.2 m allowance
East atrium gallery
L02-RM002
inside below allowance0.4 mBelow the proposed 1.2 m allowance
Occupied day-use suite
L03-RM001
outside wall and deck-3.6 mRib_R1 passes through the footprint (26 lattice samples)
Measured on the actual modelC01 baselineC02 candidateC02T taper study (not a candidate)
Fits (≥ 1.2 m)707559
Inside, below allowance355
Outside wall, inside deck700
Outside wall and deck111
Outside tower skin0016
Rooms measured81 / 8181 / 8181 / 81

Not covered: Levels L04-L24 and L27-L44 have no room layout in INT R02 (39 of 45 floors). Doors, stairs, lifts, furniture, player or camera envelopes and furnished clearances. Heights between each room's floor and clear-height top. Watertight construction, collision, LODs, UVs and any engine behaviour. Full per-room results are in the JSON and CSV below.

Same geometry / saved renders

See the building.

Direct renders of the C02 candidate mesh. The interactive viewer is no longer served.

R06 intent, C01 baseline and C02.

R06 front and rear remain the controlling visual references. These are qualitative comparisons: source camera calibration is unknown, so alignment is not a dimensional test. C02 changes only what the reference differences call for; C01 stays as the baseline.

What changed from C01 (all proposals)

  • Ribs: flared blades, 16 m wide at the foot narrowing to 7 m mid-tower, on a smooth monotone path; authored foot/tip centres retained.
  • Podium: 0.6 m slabs with a curved cantilever fascia (2.3 m drop, 11 m reach) and explicit enclosure walls with a front bay.
  • Tower: smooth profile held at 63.8 × 53.2 m or wider through +135 m, then tapering to 40 × 30 m at +216 m.
  • Not yet matched: the silhouette is still more columnar than the artwork. The taper cannot begin lower without taking the unchanged L25/L26 rooms outside the skin (study below).
Required changes, presented for review.

Nothing below was changed silently. Original artwork and INT R02 layouts are intact; each change needed to close a measured conflict is presented for review.

DecisionEvidenceOptions
1. Taper vs. L25/L26 room blocksmeasured C02T: 16 of 32 tower rooms outside the skin, -4.35 to -1.69 m.Keep the late taper (C02), or shrink or relocate the 60×40 / 60×48 m room blocks for a reference-style taper.
2. Tier-1 front (atrium, galleries)measured five rooms 0.4 m inside the front wall.Deck 1 about 107.6 m deep instead of 106 m, or move the atrium and galleries about 0.8 m rearward.
3. L03-RM001 suitemeasured outside the tier-2 wall and deck; measured Rib_R1 crosses it.Relocate about 4.8 m rearward and resolve the R1 crossing by changing its proposed intermediate controls or trimming the suite.
4. Which enclosure governs each levelinterpreted L00–L02 tier 1, L03 tier 2, L25/L26 tower skin.Record the governing enclosure per level before any fit is relied on.
Taper study: what a reference-style taper costs.

C02T is a study, not a candidate and not a handoff model. It tapers from +54 m to show what a reference-style taper costs the unchanged rooms. It is not offered for download as a model; only its views and measurements are published.

Measured on the actual modelC02 candidateC02T taper study (not a candidate)
Fits (≥ 1.2 m)7559
Inside, below allowance55
Outside wall, inside deck00
Outside wall and deck11
Outside tower skin016
Rooms measured81 / 8181 / 81
Every file / 23 model files and 29 fit-coverage files

GLB not served on the website; the original model is preserved in the project. The ZIP is a website package, GLB excluded. Its original PACKAGE_MANIFEST.json, verify_package.py and import_in_blender.py are unchanged and still name the GLB; use WEBSITE_MANIFEST.json and WEBSITE_PACKAGE.md for what the ZIP contains. Keep OBJ and MTL together. In Blender, import the OBJ with Forward Axis Y and Up Axis Z. Source coordinates: metres, Z up, front −Y. The original GLB, which is not served, used Y up, front +Z. Isolated review asset: no district placement transform.

Fit-coverage set / 29 files

Public by link · noindex · no shell, placement, final-scale or engine approval; the district construction hold remains. Readiness report · C01 baseline · Original Crown Landmark handoff · Quik handoff collection