# Crown Landmark · all-room fit coverage

**Asset:** PI-BLD-0001-V01 · **Date:** 16 October 2026 · **Status:** measurement only. This approves no design, shell, placement, final scale or engine readiness.

`fit_coverage.py` tests **all 81** unchanged INT R02 room rectangles (levels L00–L03, L25, L26) against the actual GLB of a candidate: `python fit_coverage.py C01|C02|C02T`. Outputs per candidate are in `C01/`, `C02/` and `C02T/`: JSON, CSV, plan sections for every level with a layout, vertical sections and a podium close-up (PNG + SVG).

The published C01 audit (`SHELL-C01/MODEL/FIT_REVIEW.json`) covered 32 of 81 rooms (L25 and L26). This tool adds the 49 lower-floor rooms.

## Which enclosure governs each level (interpreted)

| Level | Floor z | Governing enclosure | Roof deck |
|---|---|---|---|
| L00, L01, L02 | 0 / 6 / 12 m | podium tier 1 wall line | Deck 1, +18 m |
| L03 | 18 m | podium tier 2 wall line | Deck 2, +36 m |
| L25 / L26 | 126 / 130.5 m | tower curtainwall skin, sectioned at the room's floor and clear-height top | — |

The wall line, deck outline and soffit are read from the actual GLB parts. Which enclosure governs a level is **interpreted** from R06's deck heights and needs a recorded decision. Rooms on levels 4–24 and 27–44 do not exist in INT R02 (39 of 45 floors have no layout).

## Status classes

- **FITS**: inside the wall/skin with at least the proposed 1.2 m perimeter allowance.
- **INSIDE_BELOW_ALLOWANCE**: inside, but with less than 1.2 m margin.
- **OUTSIDE_WALL_INSIDE_DECK**: outside the wall line, but inside the deck outline.
- **OUTSIDE_WALL_AND_DECK**: outside both.
- **OUTSIDE_SKIN**: a tower room outside the skin (taper study only).

Evidence labels: **measured** = distance, slice or sampled-vertex result on the actual mesh; **proposed** = the 1.2 m allowance and slab thickness; **interpreted** = which enclosure governs a level. Concerns recorded before measurement stay labelled as preliminary.

## Not covered

Floors without layouts; doors, stairs, lifts, furniture and player/camera envelopes; heights between a room's floor and clear-height top; watertight construction, collision, LODs, UVs and engine behaviour. Rib intrusion is a triangle-sample test of the rib lattice against each room footprint, not a structural check.

## Results

| Candidate | FITS | Below allowance | Outside wall, inside deck | Outside wall and deck | Outside skin |
|---|---|---|---|---|---|
| C01 baseline | 70 | 3 | 7 | 1 | 0 |
| C02 | 75 | 5 | 0 | 1 | 0 |
| C02T taper study (not a candidate) | 59 | 5 | 0 | 1 | 16 |

C01's podium findings are measured against C01's inset glazing planes (the only enclosure that candidate defines); they are an artefact of that interpretation and should be read together with the C02 wall parts.