PARADISE ISLAND - REUSABLE BUILDING DESIGN HANDOFF STANDARD PIPELINE Exterior design pack -> Quik's basic shell/blockout -> interior layout/design pack -> detailed modeling -> in-game review. One short shell review connects exterior dimensions and interior circulation. The exterior need not be finished before interior design starts. EXTERIOR COVERAGE 1. One full-height controlling master for each geometric variant. 2. Front, rear and both flanks with clear camera descriptions. 3. Elevated front/rear views and crown/roof development as needed. 4. A true-overhead roof/footprint reference or explicit plan schematic. 5. Entrance, terrace/podium, facade/junction and structural-foot details. 6. Important tight details supplied individually as well as on overview boards. 7. Compact scale card: height, footprint width/depth, floor count/spacing, podium levels, crown/roof levels, entrance clearance and local orientation. 8. A reference-priority rule for each role; mark conflicting older panels secondary. 9. Asset index/manifest, global IDs and a clear reference-pack revision. Coverage determines image count. Hero buildings may require more references. ENTERABILITY - REQUIRED FIELD fully_enterable: rooms/levels intended for broad player access. selected_rooms_enterable: defined lobby/circulation/signature rooms accessible. exterior_only: facade/shell; interior design only where needed for visible dressing. Choose a production target and record the specific accessible spaces. BLOCKOUT CHECK Height/footprint budget, facade/floor rhythm, podium/crown organization, rear reference, entrance clearance and elevator/stair/corridor space agree as one shell. Use one mesh to render consistency views. Correct the specific mismatch. INTERIOR COVERAGE - NO FIXED IMAGE COUNT Floor plan and section: rooms, levels, entrances and vertical circulation. Lobby wide and reverse: same space from two directions. Entrance inward/outward: connect interior to approved exterior. Elevator/stair core and corridor: movement through the building. Typical occupied room: everyday use. Signature story room: narrative space where applicable. Ceiling/materials/lighting/fixtures: reproducible finish and detail. Interior dimensions and openings must match the reviewed shell. VERSIONING PI-BLD-####-V## or PI-STR-####-V## remains the global asset identifier. V## changes for a deliberate geometric variant; R## changes for the handoff pack. Readable asset name + EXT/INT + R## + shot number/description follows the ID. Source boards retain historical printed revisions; explain them in the index. Verify image hashes and archive integrity after saving. Offer smaller archives.