PARADISE ISLAND - REUSABLE BUILDING DESIGN HANDOFF STANDARD

PIPELINE
Exterior design pack -> Quik's basic shell/blockout -> interior layout/design
pack -> detailed modeling -> in-game review.
One short shell review connects exterior dimensions and interior circulation.
The exterior need not be finished before interior design starts.

EXTERIOR COVERAGE
1. One full-height controlling master for each geometric variant.
2. Front, rear and both flanks with clear camera descriptions.
3. Elevated front/rear views and crown/roof development as needed.
4. A true-overhead roof/footprint reference or explicit plan schematic.
5. Entrance, terrace/podium, facade/junction and structural-foot details.
6. Important tight details supplied individually as well as on overview boards.
7. Compact scale card: height, footprint width/depth, floor count/spacing,
   podium levels, crown/roof levels, entrance clearance and local orientation.
8. A reference-priority rule for each role; mark conflicting older panels secondary.
9. Asset index/manifest, global IDs and a clear reference-pack revision.
Coverage determines image count. Hero buildings may require more references.

ENTERABILITY - REQUIRED FIELD
fully_enterable: rooms/levels intended for broad player access.
selected_rooms_enterable: defined lobby/circulation/signature rooms accessible.
exterior_only: facade/shell; interior design only where needed for visible dressing.
Choose a production target and record the specific accessible spaces.

BLOCKOUT CHECK
Height/footprint budget, facade/floor rhythm, podium/crown organization, rear
reference, entrance clearance and elevator/stair/corridor space agree as one shell.
Use one mesh to render consistency views. Correct the specific mismatch.

INTERIOR COVERAGE - NO FIXED IMAGE COUNT
Floor plan and section: rooms, levels, entrances and vertical circulation.
Lobby wide and reverse: same space from two directions.
Entrance inward/outward: connect interior to approved exterior.
Elevator/stair core and corridor: movement through the building.
Typical occupied room: everyday use.
Signature story room: narrative space where applicable.
Ceiling/materials/lighting/fixtures: reproducible finish and detail.
Interior dimensions and openings must match the reviewed shell.

VERSIONING
PI-BLD-####-V## or PI-STR-####-V## remains the global asset identifier.
V## changes for a deliberate geometric variant; R## changes for the handoff pack.
Readable asset name + EXT/INT + R## + shot number/description follows the ID.
Source boards retain historical printed revisions; explain them in the index.
Verify image hashes and archive integrity after saving. Offer smaller archives.