CROWN LANDMARK / INTERIOR DESIGN HANDOFF R02
Asset PI-BLD-0001-V01 | Crown Key | 2043
STATUS: INTERIOR DESIGN REFERENCE WITH R02 VIEW CORRECTIONS. R01 TECHNICAL PROPOSAL RETAINED.

REFERENCE AUTHORITY
Protocol R02 governs production. EXT R06 controls the external design targets; 02_Rear controls the crossed-gold rear facade, not the contradictory B02 rear panel. Master_Lobby controls public interior appearance; Master_Hospitality, Master_Council and Master_Diplomacy control their room families. Individual reverse views supplement these masters. JSON coordinates, schedules and native plan drawings govern this authored layout proposal. Perspective images do not establish measured geometry. Where an image conflicts with a doorway, count or proportion in the plan, use the plan for the first blockout and record the visual discrepancy.

SHELL AND LEVELS
Exterior targets: 240 m total height, foundation 160 x 120 m; podium decks +18/+36/+54 m, tower envelope at +54 m 68 x 54 m. Nine podium floor intervals at 6 m, 36 tower intervals at 4.5 m; roof +216 m and crown to +240 m. All are design targets, not measured values. Selected rooms enterable. Origin is tower centre at finished ground; X local right, Y local rear, Z up. Front is negative Y. No district placement ID or map transform is assigned.
L00 +0: arrival, concierge, hospitality, staff support and core.
L01 +6 and L02 +12: perimeter atrium galleries. Omit central slabs. Central atrium clear height 14 m; peripheral L02 ceiling +17.4 m with 2 m overlook opening below the central ceiling.
L03 +18: typical occupied day-use suite.
L25 +126: proposed council, waiting, celebration, corridor and view window.
L26 +130.5: proposed independent diplomacy lounge, breakfast, office and records.
The numbered levels are proposed local assignments pending shell review. The base tower envelope does not prove the upper tapered shell fits these rooms.

VIEW REALISM - R02
The approved Crown Key city layout is the working baseline; no city redesign or
new building lock is required to continue the interiors. Crown Landmark is inland.
Shots 12,15,17,18,19,21,22,25 use neutral daylight beyond the glass. These are
presentation placeholders, not frosted/opaque glazing and not verified views.
Shots 01 and 03 correct the rear core panels to reflective interior surfaces.
Shot 14 replaces the small ground-level ocean backdrop with inland planting and
nearby facades. Other images remain unchanged. See VIEW_CORRECTIONS_R02.csv.
Build rooms, furniture, finishes and lighting now using the retained proposal.
Keep the exterior environment separate. Later, export background views from one
approved district scene using actual room location, floor elevation and camera.
Check parallax between nearby rooms and consistency between wide/detail views.
Any retained exterior imagery is illustrative, not a source of measured geography.
Preserve the approved streets, coastline and building arrangement.

CIRCULATION AND CORE
Three passenger lift shafts use 4 x 4.8 m planning cells; cabin target 2.8 x 3.2 m. Keep two stairs and a separate service lift/MEP reserve. Stack core zones on the six scheduled levels and interpolate through intervening floors. Service lift reserve is at X=6..10, Y=-3.2..2. Ground staff route runs pantry -> inner staff corridor -> rear connector -> cross corridor -> service vestibule. Upper staff access passes the controlled cross corridor; it is not a fully segregated staff corridor. L26 east staff link feeds support independently of the public lounge. Secured records are reached through the office.
Stair target: 1.8 m clear flight, 0.30 m tread; two-flight arrangement with 36 total risers for 6 m or 28 for 4.5 m. Final landings, doors, headroom and engine movement need blockout testing. These are game-environment planning targets, not building-code certification.

STORY AND BLOCKING
Atlas L18 / PI-LOC-018 requires vote room, waiting, celebration, empty corridor and view window. L19 / PI-LOC-019 requires lounge, breakfast, private office and secured records with independent suite access. AK07 requires four principals and observers with finance-grade restraint. The exact host building and placement remain proposed. Preserve the game twelve-meeting/refusal sequence separately from the novel thirteenth vote.
Council table target 7.2 x 3.6 m: four voting positions plus eight observer seats in the proposed blocking. Novel vote order: Fatima, Gunshine, hybrid Marley, Q; activation, corridor, Sophia at edge. Test audible celebration from the adjacent room. The beach is a cinematic cut, not a direct upper-floor exit. Breakfast has eight seats; diplomacy uses two sofas and four chairs as visual targets. Seating and decorative details vary slightly between concepts; primary master and schedule settle the blockout.

MODELING DELIVERY
Build the exterior shell first, check rooms against its taper, ribs and facade bays, and record accepted adjustments before detail. Keep furniture, lighting, vegetation, rugs and decor as separate reusable objects. The supplied OBJ is a metre-scale planning study with floor zones and separate wall ribbons; it is not a finished scene, joined wall mesh, collision mesh or interior model. Shared ribbons may overlap and atrium gallery edges need conversion to balustrades. No texture maps, UVs, LODs or collision are supplied. Use JSON/SVG to rebuild coherent geometry and export definitive cameras from the approved model.
