  "asset_id": "PI-BLD-0006-V01",
  "purpose": "Prepare the Frame Tall frame/core/floor-kit coordination record and identify which shared parts can be tested across the height family.",
  "scope_basis": "P2; proposed Tier C. Catalog concept only; no dedicated pack, placement, shell revision or engine evidence. Register program is lobby, typical office kit and selected shared meeting room; each height variant requires its own exoframe, intrusion, clear-height and service-core check.",
  "components": [
    {
      "name": "Exoframe bay",
      "role": "The register requires the structural bay to be coordinated, but gives no span or module dimensions.",
      "evidence_kind": "source_record",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
      ],
      "open_questions": [
        "Which source reference controls bay rhythm and where does it join slabs/façade?"
      ]
    },
    {
      "name": "Structural intrusions and clear floor",
      "role": "The register calls out intrusions and clear floor height as explicit fit checks.",
      "evidence_kind": "source_record",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
      ],
      "open_questions": [
        "Which structure zones reduce usable room/circulation clearance in this variant?"
      ]
    },
    {
      "name": "Service core",
      "role": "A service core is in the proposed program and must be coordinated with the frame.",
      "evidence_kind": "source_record",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
      ],
      "open_questions": [
        "What core location/continuity is supported by the controlling references?"
      ]
    },
    {
      "name": "Office / meeting room kit",
      "role": "Typical office and selected shared meeting room are proposed, not selected/approved.",
      "evidence_kind": "source_record",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
      ],
      "open_questions": [
        "Which representative meeting space is needed and how does it connect to the core?"
      ]
    },
    {
      "name": "Variant envelope",
      "role": "Check the tall variant’s exoframe/core/clear-floor relationships independently across its proposed stack.",
      "evidence_kind": "proposed_design",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
      ],
      "open_questions": [
        "What dimensions distinguish this variant, and which parts are genuinely reusable across siblings?"
      ]
    },
    {
      "name": "Tall taper and crossing exoframe",
      "role": "Notes describe a tapered glass body and large crossing diagonals. The card shows several members while the close render reads as one dominant A; the apparent taper also differs. These remain concept conflicts.",
      "evidence_kind": "source_notes",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
        "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv"
      ],
      "open_questions": [
        "Which frame layout and faces control?",
        "Is the taper genuine or a perspective effect?"
      ]
    }
  ],
  "modeling_sequence": [
    {
      "step": 1,
      "title": "Record A-frame/taper conflicts",
      "action": "Use the notes/index to list the multiple-diagonal versus dominant-A reading and taper question without resolving geometry.",
      "gate": "Legend chooses authority before frame geometry is modeled.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
        "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv"
      ]
    },
    {
      "step": 2,
      "title": "Diagram exoframe and core",
      "action": "Prepare a section/elevation with frame bays, floor lines, core zones and known structural intrusions; leave values blank where no source exists.",
      "gate": "Every numeric value requires a source, status, owner and reviewer.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json"
      ]
    },
    {
      "step": 3,
      "title": "Check one office/meeting kit",
      "action": "Place a schematic typical office and selected meeting-room zone against the frame/core diagram.",
      "gate": "Clear dimensions and circulation are candidates until the shell is measured and furnished-player reviewed.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/templates/ASSET_BRIEF_TEMPLATE.json",
        "production/protocols/building/R05/GUIDE.md"
      ]
    },
    {
      "step": 4,
      "title": "Compare variant reuse boundaries",
      "action": "Classify candidate repeat parts versus variant-specific frame/envelope/core geometry.",
      "gate": "Do not turn a cosmetic/material reuse candidate into geometry reuse without compatible interfaces.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/GUIDE.md"
      ]
    },
    {
      "step": 5,
      "title": "Return variant evidence plan",
      "action": "List each required plan/section and return measurement, route, collision and player-camera evidence needed later.",
      "gate": "No shell or engine acceptance is implied.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json",
        "production/protocols/building/R05/GUIDE.md"
      ]
    }
  ],
  "required_views": [
    {
      "view": "Frame Tall front/three-quarter view",
      "purpose": "Show the tapered body and frame pattern against selected authority; notes flag a card/render disagreement.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
        "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv"
      ]
    },
    {
      "view": "Typical floor/core plan",
      "purpose": "Show the office kit, service core and structural intrusions relative to the candidate clear room zone.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/templates/ASSET_BRIEF_TEMPLATE.json"
      ]
    },
    {
      "view": "Frame/core vertical section",
      "purpose": "Show level relationships, clear-height questions, frame continuity and service-core stack.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json"
      ]
    },
    {
      "view": "Meeting-room sample view",
      "purpose": "Test one selected shared meeting room against the frame and player/camera envelope after scope is chosen.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/GUIDE.md"
      ]
    }
  ],
  "candidate_kit_ids": [
    "CK-KIT-LOBBY",
    "CK-KIT-CORE",
    "CK-KIT-OFFICE",
    "CK-KIT-SERVICE",
    "CK-KIT-EXOFRAME",
    "CK-KIT-PROPS"
  ],
  "dependencies": [
    {
      "asset_id": "PI-BLD-0006-V02",
      "relationship": "Sibling-height comparison only; the register requires verifying each height variant and does not authorize scaled copies.",
      "status": "proposed",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
        "production/assets/buildings/PI-BLD-0006-V02/VISUAL_NOTES.md"
      ]
    },
    {
      "asset_id": "PI-BLD-0006-V03",
      "relationship": "Sibling-height comparison only; the register requires verifying each height variant and does not authorize scaled copies.",
      "status": "proposed",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
        "production/assets/buildings/PI-BLD-0006-V03/VISUAL_NOTES.md"
      ]
    }
  ],
  "decision_queue": [
    {
      "question": "Which frame pattern controls, and is the glass body actually tapered?",
      "owner": "Legend",
      "resolution_evidence": "Named authority, annotated elevation and candidate plan/section; perspective alone does not resolve taper.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
        "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv"
      ]
    },
    {
      "question": "What clear floor height and structural intrusion zones must the office kit preserve?",
      "owner": "Legend with design/layout author",
      "resolution_evidence": "Measured section and furnished clear-room plan, followed by candidate-shell fit evidence.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json",
        "production/protocols/building/R05/GUIDE.md"
      ]
    },
    {
      "question": "What is the service-core arrangement and how does it connect to the lobby and typical floors?",
      "owner": "Legend; Quik provides later measured engine evidence",
      "resolution_evidence": "Reviewed core/access plan and shell continuity evidence.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/templates/ASSET_BRIEF_TEMPLATE.json",
        "production/protocols/building/R05/GUIDE.md"
      ]
    },
    {
      "question": "Which frame parts can actually be reused across Tall, Mid and Compact without changing geometry?",
      "owner": "Legend with design/layout author",
      "resolution_evidence": "Side-by-side variant interface comparison and an R05 reuse record.",
      "source_paths": [
        "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
        "production/protocols/building/R05/GUIDE.md"
      ]
    }
  ],
  "friday_work": {
    "can_prepare": [
      "Keep the multiple-diagonal/card versus dominant-A/render and taper conflicts open; request frame-foot, balcony and roof-end sections.",
      "Identify candidate office/meeting kit interfaces and mark the frame, intrusion and clear-height values still missing."
    ],
    "requires_decision": [
      "Legend review of each variant envelope and the proposed shared meeting-room scope.",
      "Approved/sourced frame, core and clear-height dimensions before a shell can be accepted."
    ],
    "return_evidence": [
      "Independent Frame Tall plan/section plus comparison against PI-BLD-0006-V02, PI-BLD-0006-V03 with all source revisions named.",
      "Later shell-fit and player/camera evidence for frame intrusion, clear floor, core continuity and the selected meeting room."
    ]
  },
  "schema_version": 1,
  "revision": "R01",
  "date": "2026-10-16",
  "status": "DRAFT_PRODUCTION_PREP",
  "status_notice": "Draft preparation only; not an issued reference pack, shell, approval or construction release. Foundation hold remains in force; preparation does not authorize construction or accept dimensions, placement or engine readiness.",
  "name": "Frame Tall",
  "kind": "building",
  "priority": "P2",
  "protocol_revisions": {
    "building": "R05",
    "district": "R05",
    "spatial_imagery": "R01"
  },
  "source_main_commit": "8e9c5949400a528e0e16274e137653584a5560eb",
  "register_tasks": [
    {
      "id": "PI-BLD-0006-V01-01",
      "work": "Confirm parcel/placement and controlling exterior references; reconcile current UE state",
      "status": "pending"
    },
    {
      "id": "PI-BLD-0006-V01-02",
      "work": "Approve envelope, levels, core and dimensions; record scale source and exceptions",
      "status": "pending"
    },
    {
      "id": "PI-BLD-0006-V01-03",
      "work": "Issue dimensioned site/ground/roof plans, distinct-floor plans and necessary sections",
      "status": "pending"
    },
    {
      "id": "PI-BLD-0006-V01-04",
      "work": "Coordinate exoframe bay, structural intrusions, clear floor height and service core; verify each height variant.",
      "status": "pending"
    },
    {
      "id": "PI-BLD-0006-V01-05",
      "work": "Select enterability and implement only the approved room/kit program: Lobby, typical office kit, selected shared meeting room",
      "status": "candidate_scope"
    },
    {
      "id": "PI-BLD-0006-V01-06",
      "work": "Review shell fit and a furnished/player-camera sample; derive actual window/site views",
      "status": "pending"
    },
    {
      "id": "PI-BLD-0006-V01-07",
      "work": "Verify collision, navigation, access, streaming, materials and performance; issue manifest and current commit evidence",
      "status": "pending"
    }
  ],
  "authoritative_dimension_contract": "production/assets/buildings/PI-BLD-0006-V01/BUILDING_DIMENSIONS.json",
  "dimensions_status": "unset",
  "input_record": {
    "asset_id": "PI-BLD-0006-V01",
    "purpose": "Prepare the Frame Tall frame/core/floor-kit coordination record and identify which shared parts can be tested across the height family.",
    "scope_basis": "P2; proposed Tier C. Catalog concept only; no dedicated pack, placement, shell revision or engine evidence. Register program is lobby, typical office kit and selected shared meeting room; each height variant requires its own exoframe, intrusion, clear-height and service-core check.",
    "components": [
      {
        "name": "Exoframe bay",
        "role": "The register requires the structural bay to be coordinated, but gives no span or module dimensions.",
        "evidence_kind": "source_record",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
        ],
        "open_questions": [
          "Which source reference controls bay rhythm and where does it join slabs/façade?"
        ]
      },
      {
        "name": "Structural intrusions and clear floor",
        "role": "The register calls out intrusions and clear floor height as explicit fit checks.",
        "evidence_kind": "source_record",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
        ],
        "open_questions": [
          "Which structure zones reduce usable room/circulation clearance in this variant?"
        ]
      },
      {
        "name": "Service core",
        "role": "A service core is in the proposed program and must be coordinated with the frame.",
        "evidence_kind": "source_record",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
        ],
        "open_questions": [
          "What core location/continuity is supported by the controlling references?"
        ]
      },
      {
        "name": "Office / meeting room kit",
        "role": "Typical office and selected shared meeting room are proposed, not selected/approved.",
        "evidence_kind": "source_record",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
        ],
        "open_questions": [
          "Which representative meeting space is needed and how does it connect to the core?"
        ]
      },
      {
        "name": "Variant envelope",
        "role": "Check the tall variant’s exoframe/core/clear-floor relationships independently across its proposed stack.",
        "evidence_kind": "proposed_design",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json"
        ],
        "open_questions": [
          "What dimensions distinguish this variant, and which parts are genuinely reusable across siblings?"
        ]
      },
      {
        "name": "Tall taper and crossing exoframe",
        "role": "Notes describe a tapered glass body and large crossing diagonals. The card shows several members while the close render reads as one dominant A; the apparent taper also differs. These remain concept conflicts.",
        "evidence_kind": "source_notes",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
          "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv"
        ],
        "open_questions": [
          "Which frame layout and faces control?",
          "Is the taper genuine or a perspective effect?"
        ]
      }
    ],
    "modeling_sequence": [
      {
        "step": 1,
        "title": "Record A-frame/taper conflicts",
        "action": "Use the notes/index to list the multiple-diagonal versus dominant-A reading and taper question without resolving geometry.",
        "gate": "Legend chooses authority before frame geometry is modeled.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
          "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv"
        ]
      },
      {
        "step": 2,
        "title": "Diagram exoframe and core",
        "action": "Prepare a section/elevation with frame bays, floor lines, core zones and known structural intrusions; leave values blank where no source exists.",
        "gate": "Every numeric value requires a source, status, owner and reviewer.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json"
        ]
      },
      {
        "step": 3,
        "title": "Check one office/meeting kit",
        "action": "Place a schematic typical office and selected meeting-room zone against the frame/core diagram.",
        "gate": "Clear dimensions and circulation are candidates until the shell is measured and furnished-player reviewed.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/templates/ASSET_BRIEF_TEMPLATE.json",
          "production/protocols/building/R05/GUIDE.md"
        ]
      },
      {
        "step": 4,
        "title": "Compare variant reuse boundaries",
        "action": "Classify candidate repeat parts versus variant-specific frame/envelope/core geometry.",
        "gate": "Do not turn a cosmetic/material reuse candidate into geometry reuse without compatible interfaces.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/GUIDE.md"
        ]
      },
      {
        "step": 5,
        "title": "Return variant evidence plan",
        "action": "List each required plan/section and return measurement, route, collision and player-camera evidence needed later.",
        "gate": "No shell or engine acceptance is implied.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json",
          "production/protocols/building/R05/GUIDE.md"
        ]
      }
    ],
    "required_views": [
      {
        "view": "Frame Tall front/three-quarter view",
        "purpose": "Show the tapered body and frame pattern against selected authority; notes flag a card/render disagreement.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
          "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv"
        ]
      },
      {
        "view": "Typical floor/core plan",
        "purpose": "Show the office kit, service core and structural intrusions relative to the candidate clear room zone.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/templates/ASSET_BRIEF_TEMPLATE.json"
        ]
      },
      {
        "view": "Frame/core vertical section",
        "purpose": "Show level relationships, clear-height questions, frame continuity and service-core stack.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json"
        ]
      },
      {
        "view": "Meeting-room sample view",
        "purpose": "Test one selected shared meeting room against the frame and player/camera envelope after scope is chosen.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/GUIDE.md"
        ]
      }
    ],
    "candidate_kit_ids": [
      "CK-KIT-LOBBY",
      "CK-KIT-CORE",
      "CK-KIT-OFFICE",
      "CK-KIT-SERVICE",
      "CK-KIT-EXOFRAME",
      "CK-KIT-PROPS"
    ],
    "dependencies": [
      {
        "asset_id": "PI-BLD-0006-V02",
        "relationship": "Sibling-height comparison only; the register requires verifying each height variant and does not authorize scaled copies.",
        "status": "proposed",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
          "production/assets/buildings/PI-BLD-0006-V02/VISUAL_NOTES.md"
        ]
      },
      {
        "asset_id": "PI-BLD-0006-V03",
        "relationship": "Sibling-height comparison only; the register requires verifying each height variant and does not authorize scaled copies.",
        "status": "proposed",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
          "production/assets/buildings/PI-BLD-0006-V03/VISUAL_NOTES.md"
        ]
      }
    ],
    "decision_queue": [
      {
        "question": "Which frame pattern controls, and is the glass body actually tapered?",
        "owner": "Legend",
        "resolution_evidence": "Named authority, annotated elevation and candidate plan/section; perspective alone does not resolve taper.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
          "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv"
        ]
      },
      {
        "question": "What clear floor height and structural intrusion zones must the office kit preserve?",
        "owner": "Legend with design/layout author",
        "resolution_evidence": "Measured section and furnished clear-room plan, followed by candidate-shell fit evidence.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json",
          "production/protocols/building/R05/GUIDE.md"
        ]
      },
      {
        "question": "What is the service-core arrangement and how does it connect to the lobby and typical floors?",
        "owner": "Legend; Quik provides later measured engine evidence",
        "resolution_evidence": "Reviewed core/access plan and shell continuity evidence.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/templates/ASSET_BRIEF_TEMPLATE.json",
          "production/protocols/building/R05/GUIDE.md"
        ]
      },
      {
        "question": "Which frame parts can actually be reused across Tall, Mid and Compact without changing geometry?",
        "owner": "Legend with design/layout author",
        "resolution_evidence": "Side-by-side variant interface comparison and an R05 reuse record.",
        "source_paths": [
          "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
          "production/protocols/building/R05/GUIDE.md"
        ]
      }
    ],
    "friday_work": {
      "can_prepare": [
        "Keep the multiple-diagonal/card versus dominant-A/render and taper conflicts open; request frame-foot, balcony and roof-end sections.",
        "Identify candidate office/meeting kit interfaces and mark the frame, intrusion and clear-height values still missing."
      ],
      "requires_decision": [
        "Legend review of each variant envelope and the proposed shared meeting-room scope.",
        "Approved/sourced frame, core and clear-height dimensions before a shell can be accepted."
      ],
      "return_evidence": [
        "Independent Frame Tall plan/section plus comparison against PI-BLD-0006-V02, PI-BLD-0006-V03 with all source revisions named.",
        "Later shell-fit and player/camera evidence for frame intrusion, clear floor, core continuity and the selected meeting room."
      ]
    }
  },
  "source_hash_inventory": [
    {
      "path": "docs/current-decisions.md",
      "sha256": "8001f9a1c613b326b030da3ace10947a3021dc12f9273b7c7fa46d0ade10d382"
    },
    {
      "path": "production/assets/buildings/PI-BLD-0006-V01/BUILDING_DIMENSIONS.json",
      "sha256": "fc585237d87e6420f0f0f35c65f1b87fe68fe62006007723ad4c282910590b6b"
    },
    {
      "path": "production/assets/buildings/PI-BLD-0006-V01/REFERENCE_INDEX.csv",
      "sha256": "c478394e09200e4b0c23cd6c109759c72d8f918ed0fe241cd0a89964712a8a1e"
    },
    {
      "path": "production/assets/buildings/PI-BLD-0006-V01/VISUAL_NOTES.md",
      "sha256": "6859eaca6cf97390bc18378e5333738830b616e3ce6d6d80b5cb7fbfba278b66"
    },
    {
      "path": "production/assets/buildings/PI-BLD-0006-V02/VISUAL_NOTES.md",
      "sha256": "a5b5e07f5df5c81b3fa8977b41d57f0f0ba759ce3b66dce3d3359f484a06d4a2"
    },
    {
      "path": "production/assets/buildings/PI-BLD-0006-V03/VISUAL_NOTES.md",
      "sha256": "ea05171ae8cf8a9787d1188fccd9be977473563410415c0a2341207fa1ef69f1"
    },
    {
      "path": "production/districts/D02-CrownKey/planning/BUILD_REGISTER.json",
      "sha256": "bb0a893c54a83f490e9ff59197e593ea1093a393209c7714d57997cd3c06df3e"
    },
    {
      "path": "production/districts/D02-CrownKey/planning/prep/R01/ASSET_INPUTS_A.json",
      "sha256": "8193933c210b0cfaa825428aae1a0d1d2b2fbe8f11d6c7befc0db81d7892d2d4"
    },
    {
      "path": "production/districts/D02-CrownKey/planning/prep/R01/KIT_CATALOG.json",
      "sha256": "52525e0754aee464c84793b3b3cfe2b6ae4c95981fd2bf3e67c2d91c02ada0b9"
    },
    {
      "path": "production/protocols/building/R05/GUIDE.md",
      "sha256": "006818490740b4bd9e3994a428da95390f9f4dd987c6fd6f67a8dd1dbbc24509"
    },
    {
      "path": "production/protocols/building/R05/README.md",
      "sha256": "ecb4c6b0bf144a5da037ba8817528c40cb59ce272bc9ca63b3d187e704dc2715"
    },
    {
      "path": "production/protocols/building/R05/templates/ASSET_BRIEF_TEMPLATE.json",
      "sha256": "d6f80614e4f7d87f7cd569c7b1320cf6ad58c2021fab1955ff274a157d8df054"
    },
    {
      "path": "production/protocols/building/R05/templates/BUILDING_DIMENSIONS.json",
      "sha256": "46fefd72cb9e5bd0b1e98822a1773401f96c35d91ce57fc821d3bbc624e69631"
    },
    {
      "path": "production/protocols/current.json",
      "sha256": "c7be63113d117523e6b2e608149e6b31620f2f50436f4fbbeebdd1ffb005881a"
    },
    {
      "path": "production/protocols/district/R05/README.md",
      "sha256": "f95ad3a6c25f181898fd3be47eac800b39b5f1790387f8e93d5450e75ace5a7d"
    },
    {
      "path": "production/workflows/spatial-imagery/R01/GUIDE.md",
      "sha256": "288df4dc11896d4e606f8dc49f8b1a6969679d1fad50fad7595f3e2c8b9ad173"
    }
  ]
}