  "id": "F1",
  "task": 1,
  "label": "measured",
  "subject": "L03-RM001 / Rib_R1",
  "finding": "Rib_R1 solid enters the room from z=22.00 (4.00 m above L03 floor z=18) to ceiling z=23.40; slice area in room 0.085 m2 @22.25, 0.55 @22.75, 1.19 @23.25, 1.40 @23.39 (max); plan envelope 1.417 m2, x -38.00..-37.12, y -40.42..-37.89; max depth from room edge 0.873 m at ceiling (0.816 m at z=23.3). Intrusion is overhead only (4.0-5.4 m above floor). Nearest door L03-D001 is 22.2 m away; no door within 1.0 m."
 },
 {
  "id": "F2",
  "task": 1,
  "label": "measured",
  "subject": "all 81 rooms",
  "finding": "Only L03-RM001 has any Rib_/Gold_inner_/Crown_glass_/Mullion_/Storey_band_/atrium-gold/amber-skin/cap solid or surface inside its rectangle and z range (fine sweep 0.25 m from z_bottom+0.1 to z_top-0.1 plus the three requested heights). Tower rooms L25/L26: nothing inside."
 },
 {
  "id": "F3",
  "task": 2,
  "label": "measured",
  "subject": "published rib_intrusions column",
  "finding": "Published: 1 room, L03-RM001 {Rib_R1: 26 samples}; all other 80 rooms {}. Mine: same 1 room, same part. Room-list agreement 81/81, 0 disagreements. Published test names only Rib_*; widening to Gold_inner/Mullion/Storey_band/atrium parts adds no rooms. Published value is a surface-sample count, not an area; mine is slice area 1.40 m2 max."
 },
 {
  "id": "F4",
  "task": 2,
  "label": "measured",
  "subject": "3-height scheme",
  "finding": "For L03-RM001 the three requested heights (z_bottom+0.1, mid, z_top-0.1) detect Rib_R1 only at z_top-0.1=23.3 (area 1.19 m2); at 18.1 and 20.7 it is absent because the rib enters at z=22.0."
 },
 {
  "id": "F5",
  "task": 3,
  "label": "measured",
  "subject": "102 doors",
  "finding": "No door is blocked or narrowed by a rib/mullion/storey band. Nearest Rib_/Gold_inner_ to any door: 7.884 m (L26-D011, Gold_inner_R4), then 9.903 (L25-D006, Rib_R6). Nearest mullion/storey band: 4.512 m (L26-D010, L26-D011, Storey_band_18), 5.164 (L26-D004). Nearest atrium/crossed-gold/amber skin: 5.364 (L26-D004). No door has a rib-family part within 1.0 m. Mullions/bands do not exist below z=53.9, so L00-L03 doors have none in range."
 },
 {
  "id": "F6",
  "task": 3,
  "label": "measured",
  "subject": "L00-D001 (context, not rib/mullion)",
  "finding": "Portal door L00-D001 (x=0, y=-52, 8 m x 4.5 m): Podium_wall_1 front wall plane at y=-52.4 (x -39.2..27.2, z 0.2..17.35, 16-triangle box, no portal cut-out) lies 0.4 m outside the door line across the full 8 m width. Outside rib scope; recorded because the wall closes the portal as modelled."
 },
 {
  "id": "F7",
  "task": 4,
  "label": "measured",
  "subject": "L03-RM001 vs Rib_R1 shortfall",
  "finding": "Room x -38..-14, y -48..-24, z 18..23.4. Rib_R1 overlap on west edge: depth 0.873 m at ceiling. Minimum rigid shift of the room to clear all Rib_R1 solids over the full z range: +x 0.880 m (east); +y (rearward) 10.115 m; -y (frontward) 16.425 m; -x 30.005 m. A 4.8 m rearward shift (README relocation figure) still overlaps by 1.417 m2. Room area 576 m2; 574.58 m2 left after removing the envelope, 1 piece."
 },
 {
  "id": "F8",
  "task": 4,
  "label": "measured",
  "subject": "L25/L26 rib clearance",
  "finding": "Rib family is entirely outside all 32 tower rooms. Nearest Rib_/Gold_inner_ to a room rect: 2.256 m (L26-RM001 Rib_R5), 2.257 (L26-RM002 Rib_R6), 2.405 (L26-RM003 Rib_R1; L26-RM006 Rib_R2), 2.634 (L25-RM003 Rib_R6), 2.637 (L25-RM002 Rib_R5); other tower rooms 5.2 m or more, or none within 8 m. Closest of any rib/mullion/band/atrium-gold part: 1.456 m (L26-RM005 Front_atrium_gold_-1), 1.457 (L26-RM004 Front_atrium_gold_1), 1.505 (L26-RM005 Mullion_51), 1.613 (L26-RM004 Storey_band_18). Capsule sweep 0.6/0.7/0.8/1.0 m: no L25/L26 room has a gap below any value. Gap = plan distance part-to-room-rectangle edge (interpreted as clear width; the gap may lie outside the walkable envelope)."
 },
 {
  "id": "F9",
  "task": 5,
  "label": "measured",
  "subject": "room splitting",
  "finding": "No rib/mullion/band/atrium part splits any room rectangle into disconnected pieces at any sampled height, raw or with capsule erosion 0.6-1.0 m. The Rib_R1 notch in L03-RM001 leaves one piece (574.58 of 576 m2)."
 },
 {
  "id": "F10",
  "task": 1,
  "label": "measured",
  "subject": "context: other intersections (not rib/mullion)",
  "finding": "L00-RM001 (arrival atrium): Canopy_gold_edge_52 enters 0.17 m at z 5.1-7.35 (door L00-D001 within 1 m). L00-RM003: T1_front_arch_1 plan 2.86 m2 (x -37.54..-36.24, y -38.1..-35.9), up to 1.76 m from room edge, z 0.1-5.3, nearest door 13.2 m. L03-RM001: Podium_wall_2 surface at y=-44.4 crosses the full 24 m width, 3.6 m inside the room edge (room strip y -48..-44.4 lies outside the wall line). Front_amber_atrium_skin passes 0.6 m from the L00-RM001 front edge."
 }
]